Product specifications
- Model: DDS238-VAP; mini DIN rail protector relay by TOMZN.
- Supply: AC 85–300 V, 50/60 Hz; power consumption below 0.5 W.
- Overvoltage setting: 85–300 V; default 270 V.
- Undervoltage setting: 85–300 V; default 170 V.
- Over-current setting: 1–63 A, default 40 A, or 80 A.
- Timing: Active time 0.1–60 seconds; delay-on 2–255 seconds; delay-off 1–512 seconds.
- Accuracy and features: Voltage and current accuracy 0.5%; self-protection against lightning; can also operate as a cycle switch.
If external power is interrupted during cycle-switch operation, the cycle time restarts from zero. The product has no battery or wireless functionality.
Warnings/Reminders: The stated load-identification limit concerns pure-resistive, high-power equipment, including fast heaters, electromagnetic kettles and rice cookers, in apartment or rental-housing settings.
Package includes:
- TOMZN DDS238-VAP voltage protector relay.
All electronic and mechanical equipment, devices and machines sold by InterCyprus to EU countries are CE certified and carry a two year warranty. Shop with confidence at intercyprus.com, serving customers with reliable service since 2002.