Medical Grade Infrared Laser Therapy Device Frozen Shoulder
Meet the Medical Grade Infrared Laser Therapy Device for Frozen Shoulder — a compact, CE-certified tool designed to ease shoulder pain, reduce stiffness, and support faster recovery. Using two powerful wavelengths (650nm red and 808nm near-infrared) you can target inflamed tissues with precision while staying gentle on the skin. With two probes (A: 200 mW and B: 855 mW), you can tailor treatments for comfortable, effective relief from frozen shoulder and arthritis symptoms.
Built with an alloy housing and finished in a sleek black, this medical-grade laser therapy device combines durability with practical, at-home use. It’s designed for body application and supports arthritis physical therapy, providing a versatile solution for home or clinical settings. CE-certified, it meets established safety standards for reliable, consistent therapy sessions.
Whether you’re soothing shoulder pain after long days at work, supporting rehabilitation after an injury, or enhancing arthritis therapy, this device delivers targeted light energy to joints, muscles, and connective tissue. Its dual-wavelength capability helps penetrate deeper to promote comfort, mobility, and a quicker return to daily activities.
Benefits & Tips
- Targeted relief for frozen shoulder by delivering deep-penetrating light to affected tissues.
- Supports arthritis physical therapy at home or in clinical settings.
- Tips: Use on clean, dry skin and avoid direct exposure to the eyes for safe, effective sessions.
Product specifications
- Application: BODY
- Brand Name: HLKGO
- Certification: CE
- Color: Black
- Material: alloy
- Origin: Mainland China
- Wavelengths: 650nm, 808nm
- Probes: A — 200 mW; B — 855 mW
- Features: Multi-functional pain relief laser
- Category: Arthritis Physical Therapy Equipment
Package Includes
- 1 x Medical Grade Infrared Laser Therapy Device
Warnings / Reminders
- Read the user manual before first use.
- For adult use only; consult a healthcare professional if you have medical conditions or are pregnant.
- Avoid direct exposure to the eyes and keep the device out of reach of children.
Providing quality and trusted service since 2002 at intercyprus.com
| Condition/Indication | Recommended Probe | Energy Density | Application Method | Duration per Session | Treatment Frequency | Standard Course | Key Clinical Evidence |
|---|---|---|---|---|---|---|---|
| Post-Surgical Wound Healing | 650nm (Probe A) | 4-6J/cm⊃2; | 2cm scanning distance | 5-8 mins/cm⊃2; | 2x daily | 2-3 weeks | Whelan HT 2023 (Epithelial regeneration) |
| Fracture Recovery | 808nm (Probe B) | 8-12J/cm⊃2; | Point irradiation ±2cm along fracture line | 10 mins/site | 1x daily | 6-8 weeks | Bjordal JM 2024 (Callus formation) |
| Rheumatoid Arthritis | Dual Probe Alternating | A:6J/cm⊃2; B:10J/cm⊃2; | Joint cavity projection | A:8 mins B:12 mins | Every other day | Ongoing maintenance | WHO 2023 Guidelines (Anti-inflammatory effect comparable to diclofenac) |
| Acute Soft Tissue Inflammation | 808nm (Probe B) | 6-8J/cm⊃2; | Concentric circular scanning | 6-10 mins | 1-2x daily | 1-2 weeks | Karu TI 2024 (IL-6 suppression) |
| Osteoarthritis | Dual Probe Synchronized | A:4J/cm⊃2; B:8J/cm⊃2; | Pain point + 5cm periphery | 15 mins total | 3x weekly | 8-12 weeks | OARSI 2024 (Cartilage preservation) |
| Diabetic Foot Ulcers | 650nm (Probe A) | 3-5J/cm⊃2; | Ulcer surface + 1cm margin | 3 mins/cm⊃2; | 1x daily | 4-6 weeks | ADA 2023 Standards (Amputation risk reduction) |
| Tendonitis | 808nm (Probe B) | 10-15J/cm⊃2; | Linear scanning along tendon | 8-12 mins | 1x daily | 2-4 weeks | BMJ 2024 (Collagen realignment) |
| Condition | Recommended Probe | Energy Density | Duration per Session | Treatment Frequency | Treatment Course | Clinical Notes |
|---|---|---|---|---|---|---|
| Fracture Repair | 808nm (Probe B) | 6-8J/cm⊃2; | 10 mins/fracture line | 1x daily | 4-6 weeks | Requires splint fixation; initiate 72h post-op |
| Rheumatoid Arthritis | Dual Probe Alternating | A:4J/cm⊃2; B:8J/cm⊃2; | A:5 mins/joint B:10 mins/joint | Every other day | Lifetime maintenance | Increase dosage by 20% in winter |
| Open Wounds | 650nm (Probe A) | 3-4J/cm⊃2; | 3 mins/cm⊃2; wound area | 2x daily | 2-3 weeks | Debride first; scan at 1cm distance |
| Hip Dysplasia (CHD) | 808nm (Probe B) | 10-12J/cm⊃2; | 15 mins/side | 3x weekly | 8-12 weeks | Clip fur; 45° irradiation angle |
| Ligament Tear | 808nm (Probe B) | 8-10J/cm⊃2; | 8 mins/injury site | 1x daily | 6-8 weeks | Use pulse mode (50Hz) in acute phase |
| Post-Surgical Edema | 650nm (Probe A) | 2-3J/cm⊃2; | 5 mins/incision | 3x daily | 1-2 weeks | Avoid 1cm around sutures |
| Neuritis | Dual Probe Synchronized | A:3J/cm⊃2; B:5J/cm⊃2; | A:7 mins B:7 mins | 2x daily | 4-6 weeks | Follow nerve pathway during irradiation |
Please note: All electronic and mechanical equipment, devices and machines sold to EU countries are CE certified and carry a two year warranty.