HLKGO Dual Probe Medical Grade LLLT Bursitis Pain Relief
Meet the HLKGO Dual Probe Medical Grade LLLT Bursitis Pain Relief device—a CE-certified, black alloy handheld laser designed to target pain at the source. With a dual-probe setup and two powerful wavelengths (650 nm and 808 nm), this device delivers versatile, non-invasive relief for bursitis and arthritis-related discomfort. Probe A delivers 200 mW for precise, focused treatments, while Probe B provides 855 mW for broader coverage, making it adaptable for different treatment needs in one compact unit.
Benefits & Tips
- Dual-probe versatility: Use Probe A for precise treatment on small painful spots and Probe B for larger areas, expanding your therapy options for bursitis and arthritis.
- Multi-functional relief: A single device designed for pain relief and arthritis physical therapy needs, offering convenient at-home therapy.
- Wavelength combination: Red 650 nm and near-infrared 808 nm light work together to support comfort and recovery in body tissues.
Product specifications
- Application: BODY
- Brand: HLKGO
- Certification: CE
- Color: Black
- Material: Alloy
- Origin: Mainland China
- Wavelengths: 650 nm and 808 nm
- Probe A: 200 mW
- Probe B: 855 mW
- Feature 1: Multi-functional pain relief laser
- Feature 2: Arthritis Physical Therapy Equipment
Warnings
For body use only. Use in accordance with the product manual and guidelines.
Since 2002, intercyprus.com has been a trusted source for quality and reliability.
Condition/Indication |
Recommended Probe |
Energy Density |
Application Method |
Duration per Session |
Treatment Frequency |
Standard Course |
Key Clinical Evidence |
Post-Surgical Wound Healing |
650nm (Probe A) |
4-6J/cm⊃2; |
2cm scanning distance |
5-8 mins/cm⊃2; |
2x daily |
2-3 weeks |
Whelan HT 2023 (Epithelial regeneration) |
Fracture Recovery |
808nm (Probe B) |
8-12J/cm⊃2; |
Point irradiation ±2cm along fracture line |
10 mins/site |
1x daily |
6-8 weeks |
Bjordal JM 2024 (Callus formation) |
Rheumatoid Arthritis |
Dual Probe Alternating |
A:6J/cm⊃2; |
Joint cavity projection |
A:8 mins |
Every other day |
Ongoing maintenance |
WHO 2023 Guidelines (Anti-inflammatory effect comparable to diclofenac) |
Acute Soft Tissue Inflammation |
808nm (Probe B) |
6-8J/cm⊃2; |
Concentric circular scanning |
6-10 mins |
1-2x daily |
1-2 weeks |
Karu TI 2024 (IL-6 suppression) |
Osteoarthritis |
Dual Probe Synchronized |
A:4J/cm⊃2; |
Pain point + 5cm periphery |
15 mins total |
3x weekly |
8-12 weeks |
OARSI 2024 (Cartilage preservation) |
Diabetic Foot Ulcers |
650nm (Probe A) |
3-5J/cm⊃2; |
Ulcer surface + 1cm margin |
3 mins/cm⊃2; |
1x daily |
4-6 weeks |
ADA 2023 Standards (Amputation risk reduction) |
Tendonitis |
808nm (Probe B) |
10-15J/cm⊃2; |
Linear scanning along tendon |
8-12 mins |
1x daily |
2-4 weeks |
BMJ 2024 (Collagen realignment) |
Condition |
Recommended Probe |
Energy Density |
Duration per Session |
Treatment Frequency |
Treatment Course |
Clinical Notes |
Fracture Repair |
808nm (Probe B) |
6-8J/cm⊃2; |
10 mins/fracture line |
1x daily |
4-6 weeks |
Requires splint fixation; initiate 72h post-op |
Rheumatoid Arthritis |
Dual Probe Alternating |
A:4J/cm⊃2; |
A:5 mins/joint |
Every other day |
Lifetime maintenance |
Increase dosage by 20% in winter |
Open Wounds |
650nm (Probe A) |
3-4J/cm⊃2; |
3 mins/cm⊃2; wound area |
2x daily |
2-3 weeks |
Debride first; scan at 1cm distance |
Hip Dysplasia (CHD) |
808nm (Probe B) |
10-12J/cm⊃2; |
15 mins/side |
3x weekly |
8-12 weeks |
Clip fur; 45° irradiation angle |
Ligament Tear |
808nm (Probe B) |
8-10J/cm⊃2; |
8 mins/injury site |
1x daily |
6-8 weeks |
Use pulse mode (50Hz) in acute phase |
Post-Surgical Edema |
650nm (Probe A) |
2-3J/cm⊃2; |
5 mins/incision |
3x daily |
1-2 weeks |
Avoid 1cm around sutures |
Neuritis |
Dual Probe Synchronized |
A:3J/cm⊃2; |
A:7 mins |
2x daily |
4-6 weeks |
Follow nerve pathway during irradiation |
Please note: All electronic and mechanical equipment, devices and machines sold to EU countries are CE certified and carry a two year warranty.