Portable 1064nm LLLT Laser Therapy Device Arthritis
Introducing the Portable 1064nm LLLT Laser Therapy Device Arthritis from HLKGO—a compact, at‑home solution designed to ease arthritis discomfort and support daily mobility. This multi‑functional pain relief laser uses low‑level laser therapy (LLLT) to target joints and surrounding tissues, helping to reduce inflammation and promote comfortable movement. Built with a durable alloy body in a sleek black finish, it combines multiple wavelengths for versatile therapy and features two powerful probes for focused treatment. With CE certification, you can rely on safety and quality for regular use.
Benefits & Tips
- Arthritis pain relief at home: Target affected joints and surrounding muscles to ease stiffness and daily discomfort.
- Versatile therapy: Utilize the wavelengths 1064nm, 650nm, and 808nm for deeper and surface‑level relief depending on the area being treated.
- Portable and easy to use: The compact, alloy‑built design makes it convenient for home, clinic, or on‑the‑go sessions.
Product specifications
- Application: BODY
- Brand: HLGO
- Certification: CE
- Color: Black
- Material: Alloy
- Origin: Mainland China
- Wavelengths: 1064nm, 650nm, 808nm
- Probe A power: 200 mW
- Probe B power: 855 mW
Providing quality and trusted service since 2002 at intercyprus.com
| Condition/Indication | Recommended Probe | Energy Density | Application Method | Duration per Session | Treatment Frequency | Standard Course | Key Clinical Evidence |
|---|---|---|---|---|---|---|---|
| Post-Surgical Wound Healing | 650nm (Probe A) | 4-6J/cm⊃2; | 2cm scanning distance | 5-8 mins/cm⊃2; | 2x daily | 2-3 weeks | Whelan HT 2023 (Epithelial regeneration) |
| Fracture Recovery | 808nm (Probe B) | 8-12J/cm⊃2; | Point irradiation ±2cm along fracture line | 10 mins/site | 1x daily | 6-8 weeks | Bjordal JM 2024 (Callus formation) |
| Rheumatoid Arthritis | Dual Probe Alternating | A:6J/cm⊃2; B:10J/cm⊃2; | Joint cavity projection | A:8 mins B:12 mins | Every other day | Ongoing maintenance | WHO 2023 Guidelines (Anti-inflammatory effect comparable to diclofenac) |
| Acute Soft Tissue Inflammation | 808nm (Probe B) | 6-8J/cm⊃2; | Concentric circular scanning | 6-10 mins | 1-2x daily | 1-2 weeks | Karu TI 2024 (IL-6 suppression) |
| Osteoarthritis | Dual Probe Synchronized | A:4J/cm⊃2; B:8J/cm⊃2; | Pain point + 5cm periphery | 15 mins total | 3x weekly | 8-12 weeks | OARSI 2024 (Cartilage preservation) |
| Diabetic Foot Ulcers | 650nm (Probe A) | 3-5J/cm⊃2; | Ulcer surface + 1cm margin | 3 mins/cm⊃2; | 1x daily | 4-6 weeks | ADA 2023 Standards (Amputation risk reduction) |
| Tendonitis | 808nm (Probe B) | 10-15J/cm⊃2; | Linear scanning along tendon | 8-12 mins | 1x daily | 2-4 weeks | BMJ 2024 (Collagen realignment) |
| Condition | Recommended Probe | Energy Density | Duration per Session | Treatment Frequency | Treatment Course | Clinical Notes |
|---|---|---|---|---|---|---|
| Fracture Repair | 808nm (Probe B) | 6-8J/cm⊃2; | 10 mins/fracture line | 1x daily | 4-6 weeks | Requires splint fixation; initiate 72h post-op |
| Rheumatoid Arthritis | Dual Probe Alternating | A:4J/cm⊃2; B:8J/cm⊃2; | A:5 mins/joint B:10 mins/joint | Every other day | Lifetime maintenance | Increase dosage by 20% in winter |
| Open Wounds | 650nm (Probe A) | 3-4J/cm⊃2; | 3 mins/cm⊃2; wound area | 2x daily | 2-3 weeks | Debride first; scan at 1cm distance |
| Hip Dysplasia (CHD) | 808nm (Probe B) | 10-12J/cm⊃2; | 15 mins/side | 3x weekly | 8-12 weeks | Clip fur; 45° irradiation angle |
| Ligament Tear | 808nm (Probe B) | 8-10J/cm⊃2; | 8 mins/injury site | 1x daily | 6-8 weeks | Use pulse mode (50Hz) in acute phase |
| Post-Surgical Edema | 650nm (Probe A) | 2-3J/cm⊃2; | 5 mins/incision | 3x daily | 1-2 weeks | Avoid 1cm around sutures |
| Neuritis | Dual Probe Synchronized | A:3J/cm⊃2; B:5J/cm⊃2; | A:7 mins B:7 mins | 2x daily | 4-6 weeks | Follow nerve pathway during irradiation |
Please note: All electronic and mechanical equipment, devices and machines sold to EU countries are CE certified and carry a two year warranty.